DocumentCode :
3635515
Title :
Experimental analysis of electric parameters of a 100 t UHP electric arc furnace
Author :
Adrian Ioan Toma;Gabriel Nicolae Popa;Angela Iagăr;Sorin Ioan Deaconu
Author_Institution :
ArcelorMittal Hunedoara S.A., Iancu de Hunedoara Square, no.1, Hunedoara, Romania
fYear :
2010
fDate :
3/1/2010 12:00:00 AM
Firstpage :
919
Lastpage :
924
Abstract :
This paper presents a study of power quality problems created by a UHP electric arc furnace (EAF) operation at power system. We are analyzing an electric arc furnace of 100 t capacity used for steel melting, and the related steel treatment installation. The measurements have been made using the CA8334 three-phase power quality analyser. Experimental results show that the EAF are a substantial source of electric disturbances, such as voltage fluctuations, flicker, harmonics, and unbalance between phases. Improvement of the energetic performances of an electric arc furnace imposes a careful technical and economical analysis, for choosing the possible solutions for balancing the load on phases, improving the wave forms (current and voltage) and improving the power factor.
Keywords :
"Furnaces","Power quality","Steel","Voltage fluctuations","Power system analysis computing","Power system measurements","Power measurement","Power system harmonics","Power generation economics","Performance analysis"
Publisher :
ieee
Conference_Titel :
Industrial Technology (ICIT), 2010 IEEE International Conference on
Print_ISBN :
978-1-4244-5695-6
Type :
conf
DOI :
10.1109/ICIT.2010.5472563
Filename :
5472563
Link To Document :