DocumentCode :
3636511
Title :
An analysis on the optimal fields number of the plate-type electrostatic precipitators used in a thermoelectric power plant
Author :
Gabriel N. Popa;Victor Vaida;Sorin I. Deaconu;Ioan Şora
Author_Institution :
Faculty of Engineering, Huned., Politehnica University, Timiş
fYear :
2010
Firstpage :
232
Lastpage :
239
Abstract :
The most used deduster in industrial applications are plate-type electrostatic precipitators. They can treat high gas flows obtained from various burning processes, but their price is high. These costs depend mostly on the number of fields. An analysis was performed using experimental data collected from different plate-type electrostatic precipitators in a thermoelectric power plant. The following items were analysed: the collection efficiency, the speed distribution of the dust particles in the fields, and some electrical parameters for three types of electrostatic precipitators: with two, three and four fields.
Keywords :
"Electrostatic analysis","Electrostatic precipitators","Thermoelectricity","Power generation","Voltage control","Power supplies","Voltage transformers","Current measurement","Thyristors","Power engineering and energy"
Publisher :
ieee
Conference_Titel :
Optimization of Electrical and Electronic Equipment (OPTIM), 2010 12th International Conference on
ISSN :
1842-0133
Print_ISBN :
978-1-4244-7019-8
Type :
conf
DOI :
10.1109/OPTIM.2010.5510471
Filename :
5510471