DocumentCode
3638254
Title
Some problems related to surface temperature measurement of synchronous generator excitation winding in rotation
Author
Zlatko Hanić;Mario Vražić;Stjepan Stipetić
Author_Institution
Faculty of Electrical Engineering and Computing, Department of Electrical Machines and Automation, University of Zagreb, Croatia
fYear
2010
Abstract
This paper addresses some of the problems related to direct temperature measurement of synchronous generator excitation winding in rotation. Excitation winding temperature is used for determining the dynamic limit in a PQ diagram. The paper also addresses procedures of improving the accuracy of surface temperature measurement using the DS18B20 digital temperature probes. The paper also provides experimental results of direct temperature measurement on the surface of excitation winding conducted in the synchronous generator in the rotation.
Keywords
"Temperature measurement","Probes","Windings","Insulation","Synchronous generators","Resistance","Copper"
Publisher
ieee
Conference_Titel
Power Electronics and Motion Control Conference (EPE/PEMC), 2010 14th International
Print_ISBN
978-1-4244-7856-9
Type
conf
DOI
10.1109/EPEPEMC.2010.5606587
Filename
5606587
Link To Document