• DocumentCode
    3638254
  • Title

    Some problems related to surface temperature measurement of synchronous generator excitation winding in rotation

  • Author

    Zlatko Hanić;Mario Vražić;Stjepan Stipetić

  • Author_Institution
    Faculty of Electrical Engineering and Computing, Department of Electrical Machines and Automation, University of Zagreb, Croatia
  • fYear
    2010
  • Abstract
    This paper addresses some of the problems related to direct temperature measurement of synchronous generator excitation winding in rotation. Excitation winding temperature is used for determining the dynamic limit in a PQ diagram. The paper also addresses procedures of improving the accuracy of surface temperature measurement using the DS18B20 digital temperature probes. The paper also provides experimental results of direct temperature measurement on the surface of excitation winding conducted in the synchronous generator in the rotation.
  • Keywords
    "Temperature measurement","Probes","Windings","Insulation","Synchronous generators","Resistance","Copper"
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Motion Control Conference (EPE/PEMC), 2010 14th International
  • Print_ISBN
    978-1-4244-7856-9
  • Type

    conf

  • DOI
    10.1109/EPEPEMC.2010.5606587
  • Filename