DocumentCode :
3638857
Title :
Test method of composite insulators aged in high voltage rain chamber
Author :
Witold Bretuj;Janusz Fleszyński;Krzysztof Wieczorek
Author_Institution :
Institute of Electrical Engineering Fundamentals, Wroclaw University of Technology, Poland
fYear :
2010
Firstpage :
341
Lastpage :
344
Abstract :
Rainfall can be a dangerous hazard for outdoor composite insulators. In the paper, a laboratory method of testing of ageing resistance of aerial composite insulators exposed to high voltage and water, simulating heavy rainfall, is presented. The method is illustrated by the results which show the impact of shed profile of the composite insulator with the housing made from silicone rubber on their aging resistance.
Keywords :
"Insulators","Aging","Leakage current","Discharges","Surface discharges","Resistance","Rain"