DocumentCode
3641070
Title
Simulation study of possibilities of using limited lead mapping data for inverse solution based on multipole cardiac generator
Author
Peter Kneppo;Milan Tyšler;Marie Turzová
Author_Institution
Biomeasurements Laboratory, Institute of Measurement Science, Slovak Academy of Sciences, Dú
Volume
5
fYear
1992
Firstpage
2002
Lastpage
2003
Abstract
Forward simulation was used for computing body surface potential distribution. Three different limited lead systems have been studied using the simulated surface potential data. The electrical field of computed equivalent multipolar generators was studied in relation to the simulated one. From the results it implies that the multipolar generator equivalent in sense of surface potentials seems not sufficient for recovery of the electrical field near the spatially distributed generator and that limited lead systems give enough accurate maps for judgment about the model acceptability.
Keywords
"Lead","Correlation","Myocardium","Biological system modeling","Cardiology"