DocumentCode
3646444
Title
Test and calibration of sonobuoys in the air environment
Author
Ahmet Kuzu;Üveys Danış;Engin Kurt;Engin Karabulut;Demet Şahinkaya;Ahmet Kaplaner;Serdar Birecik;Bülent Özumut;Eyüp Bilgiç
Author_Institution
Bİ
fYear
2012
fDate
4/1/2012 12:00:00 AM
Firstpage
1
Lastpage
4
Abstract
In this paper, a method for calibrating and testing DIFAR sonobuoy multiplexer without sea or water is proposed. For this purpose; the architecture of DIFAR sonobuoy is introduced, calibration factors are expressed, calibration and test environment in terms of hardware and software are described, calibration and test procedure is explained, and finally, laboratory test results of a sonobuoy calibrated in that environment is given and discussed.
Keywords
"Frequency modulation","Radio frequency","Calibration","Multiplexing","Encyclopedias","Band pass filters","Standards"
Publisher
ieee
Conference_Titel
Signal Processing and Communications Applications Conference (SIU), 2012 20th
Print_ISBN
978-1-4673-0055-1
Type
conf
DOI
10.1109/SIU.2012.6204426
Filename
6204426
Link To Document