DocumentCode
3647176
Title
Verification of the system for indirect temperatures measurement in the massive batch
Author
Marek Laciak;Ján Kačur;Milan Durdán
Author_Institution
Institute of Control and Informatization of Production Processes, Faculty BERG, Technical University of Koš
fYear
2012
fDate
5/1/2012 12:00:00 AM
Firstpage
413
Lastpage
417
Abstract
This paper presents verification of the system for indirect temperatures measurement (SITM) in the massive batch. This system is based on direct measurement of the atmosphere temperature in the furnace space between safety cover (bell) and the coil. SITM calculates temperature field inside the coil by continually at time based on continually measurement of the atmosphere temperature TA. At annealing of the steel coils are unknown temperatures inside annealed roll because it is not possible to measure continually by direct (destruction of the batch, possible defect of the temperature sensor at manipulation with the batch etc.). The missing information about temperature behavior inside steel coil can lead to the extension or shorten of annealing duration. By extension of annealing duration lead to increase of the energy cost and its shortening can lead to decrease quality of annealed batch.
Keywords
"Temperature measurement","Coils","Atmospheric measurements","Annealing","Atmospheric modeling","Steel","Heating"
Publisher
ieee
Conference_Titel
Carpathian Control Conference (ICCC), 2012 13th International
Print_ISBN
978-1-4577-1867-0
Type
conf
DOI
10.1109/CarpathianCC.2012.6228678
Filename
6228678
Link To Document