• DocumentCode
    3647176
  • Title

    Verification of the system for indirect temperatures measurement in the massive batch

  • Author

    Marek Laciak;Ján Kačur;Milan Durdán

  • Author_Institution
    Institute of Control and Informatization of Production Processes, Faculty BERG, Technical University of Koš
  • fYear
    2012
  • fDate
    5/1/2012 12:00:00 AM
  • Firstpage
    413
  • Lastpage
    417
  • Abstract
    This paper presents verification of the system for indirect temperatures measurement (SITM) in the massive batch. This system is based on direct measurement of the atmosphere temperature in the furnace space between safety cover (bell) and the coil. SITM calculates temperature field inside the coil by continually at time based on continually measurement of the atmosphere temperature TA. At annealing of the steel coils are unknown temperatures inside annealed roll because it is not possible to measure continually by direct (destruction of the batch, possible defect of the temperature sensor at manipulation with the batch etc.). The missing information about temperature behavior inside steel coil can lead to the extension or shorten of annealing duration. By extension of annealing duration lead to increase of the energy cost and its shortening can lead to decrease quality of annealed batch.
  • Keywords
    "Temperature measurement","Coils","Atmospheric measurements","Annealing","Atmospheric modeling","Steel","Heating"
  • Publisher
    ieee
  • Conference_Titel
    Carpathian Control Conference (ICCC), 2012 13th International
  • Print_ISBN
    978-1-4577-1867-0
  • Type

    conf

  • DOI
    10.1109/CarpathianCC.2012.6228678
  • Filename
    6228678