DocumentCode
3647761
Title
Comparison of the Reference Step Method with a MI 8000/8001 potentiometer
Author
Martin Šíra;Murray Early;Jiří Streit;Laurie Christian
Author_Institution
Czech Metrology Institute, Okruž
fYear
2012
fDate
7/1/2012 12:00:00 AM
Firstpage
540
Lastpage
541
Abstract
This paper summarizes a comparison between two methods of building the voltage scale. The first one is the Reference Step Method developed at the Measurement Standards Laboratory of New Zealand. The second one is based on a binary potentiometer represented by the MI 8000/8001 instrument. Both methods were used to calibrate voltage ratios of a Fluke 5720A calibrator. Preliminary results showed good agreement except for one measured point.
Keywords
"Potentiometers","Voltage measurement","Uncertainty","Voltmeters","Measurement standards","Laboratories","Software"
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2012 Conference on
ISSN
0589-1485
Print_ISBN
978-1-4673-0439-9
Electronic_ISBN
2160-0171
Type
conf
DOI
10.1109/CPEM.2012.6251042
Filename
6251042
Link To Document