• DocumentCode
    3648028
  • Title

    Impact of unbalance in harmonic polluted power networks

  • Author

    A. Miron;M. Chindriş;A. Cziker

  • Author_Institution
    Technical University of Cluj - Napoca, Electrical Engineering Faculty, Power Systems and Marketing Department, 28th Memorandumului Street, 400114, (Romania)
  • fYear
    2012
  • fDate
    6/1/2012 12:00:00 AM
  • Firstpage
    674
  • Lastpage
    678
  • Abstract
    The paper tackles an issue that concerns both the suppliers and consumers of electric energy: power losses in distribution power networks. On the other hand, the harmonic pollution in power networks has become a permanent issue, and in many situations along with the unbalance determines a steady state that is unbalanced and non-sinusoidal. In the design and exploitation stage the power engineers calculate the power losses considering the ideal case (sinusoidal and balanced), approach that brings many disadvantages. Thus, the authors propose a methodology for power losses calculus that take in consideration the existence of unbalance and harmonic pollution. The suggested method implies the use of the power quality indices that characterize the real steady state.
  • Keywords
    "Harmonic analysis","Power system harmonics","Conductors","Resistance","Steady-state","Calculus"
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), 2012 International Symposium on
  • Print_ISBN
    978-1-4673-1299-8
  • Type

    conf

  • DOI
    10.1109/SPEEDAM.2012.6264475
  • Filename