    Heart motion measurement with three dimensional sonomicrometry and acceleration sensing

  • Author

    Tetsuya Horiuchi;E. Erdem Tuna;Ken Masamune;M. Cenk Çavuşoğlu

  • Author_Institution
    Graduate School of Information Science and Technology, University of Tokyo, 113-8656 Japan
  • fYear
    2012
  • Firstpage
    4143
  • Lastpage
    4149
  • Abstract
    In robotic assisted beating heart surgery, the goal is to develop a robotic system that can actively cancel heart motion by closely following a point of interest (POI) on the heart surface, a process called Active Relative Motion Canceling (ARMC). In order to track and cancel POI motion precisely, control algorithms require good quality heart motion data. In this paper, a novel method is described which uses a particle filter to estimate the three-dimensional location of POI on heart surface by using measurements obtained from sonomicrometry along with an accelerometer. The new method employs a differential probability approach to increase the accuracy of the particle filter. The performance of the proposed method is evaluated by simulations.
  • Keywords
    "Heart","Accelerometers","Acceleration","Crystals","Position measurement","Surgery","Atmospheric measurements"