DocumentCode
3650983
Title
Operating limits of underexcited synchronous generator
Author
Zlatko Maljković;Ivan Gašparać
Author_Institution
University of Zagreb, Faculty of Electrical Engineering and Computing, Department of Electrical Machines, Drives and Automation, Zagreb, Croatia
fYear
2013
fDate
5/1/2013 12:00:00 AM
Firstpage
1374
Lastpage
1377
Abstract
Standard power chart of synchronous generator has its limit defined by practical stability limit and by field current minimum in the underexcitation quadrant. However, during the time, some generators have shown certain sensitivity during the permanent underexcited operation even in the stabile operating area due to local heating of magnetic conductive parts in the end region of the machine. Underexcited operation is usually required in case of raised network voltage while the active power demands are lowered. Precise knowledge of limits of underexcited operation ability enables precise planning of system reactive power trading. Some world experiences and axial magnetic field measurements in the end region of synchronous hydro and turbine generator are presented. Based on mentioned measurements, it is possible to define real power chart which almost always deviates in capacitive operating area compared to manufacturer´s diagram.
Keywords
"Generators","Temperature measurement","Probes","Reactive power","Stators","Magnetic flux","Vectors"
Publisher
ieee
Conference_Titel
Power Engineering, Energy and Electrical Drives (POWERENG), 2013 Fourth International Conference on
ISSN
2155-5516
Electronic_ISBN
2155-5532
Type
conf
DOI
10.1109/PowerEng.2013.6635814
Filename
6635814
Link To Document