DocumentCode :
3653043
Title :
Influence of space charge on breakdown strength of PET foil
Author :
A. Krowinski;A. Kacprzyk;B. Lowkis;K. Wojcik
Author_Institution :
Inst. of Electr. Eng., Wroclaw Tech. Univ., Poland
fYear :
1989
fDate :
6/11/1905 12:00:00 AM
Firstpage :
369
Lastpage :
373
Abstract :
Results of studies on the influence of the space charge implanted by corona charging or electron-beam irradiation on the electric strength of PET (polyethylene terephthalate) foil are presented. Values of impulse breakdown voltage as a function of corona charging voltage are presented for 36- mu m and 180- mu m PET foil samples. It is shown that for both thicknesses the breakdown voltage tends to increase in the case of positive corona voltage and to decrease in the case of negative corona voltage. This tendency was observed only when the measurements were performed at the positive voltage on the electrode.
Keywords :
"Space charge","Electric breakdown","Positron emission tomography","Breakdown voltage","Electrodes","Corona","Voltage measurement","Electron beams","Performance evaluation","Partial discharge measurement"
Publisher :
ieee
Conference_Titel :
Conduction and Breakdown in Solid Dielectrics, 1989., Proceedings of the 3rd International Conference on
Type :
conf
DOI :
10.1109/ICSD.1989.69222
Filename :
69222
Link To Document :
بازگشت