DocumentCode :
36537
Title :
A New Method to Measure Directional Modulation Transfer Function Using Sphere Phantoms in a Cone Beam Computed Tomography System
Author :
Changwoo Lee ; Jongduk Baek
Author_Institution :
Sch. of Integrated Technol., Yonsei Univ., Incheon, South Korea
Volume :
34
Issue :
4
fYear :
2015
fDate :
Apr-15
Firstpage :
902
Lastpage :
910
Abstract :
We propose a new method to measure directional modulation transfer function (MTF) using sphere phantoms in a cone beam computed tomography (CBCT) system. To measure spatially varying 3-D MTFs, we model FDK reconstruction in local regions and calculate the plane integrals of an ideal sphere phantom and reconstructed sphere phantoms. Then, we modify the Richardson-Lucy (RL) deconvolution method to relax the non-negativity constraint in RL deconvolution and apply it to estimate the directional plane spread functions (PlSFs). Directional MTFs are calculated by taking the modulus of the Fourier transform of the estimated directional PlSFs. To validate the proposed method, we simulate ideal 3-D MTFs and compare them with directional MTFs measured by simulation and experimental data along three major axes. For quantitative evaluation, we compare full-width at half-maximum (FWHM) and full-width at tenth-maximum (FWTM) of measured and ideal directional MTFs. The measured directional MTFs from simulation and experimental data show excellent agreement with the ideal directional MTFs, demonstrating the effectiveness of the proposed method to estimate directional MTFs in a CBCT system.
Keywords :
Fourier transforms; computerised tomography; deconvolution; image reconstruction; medical image processing; optical transfer function; phantoms; CBCT system; FDK reconstruction; FWHM; FWTM; Fourier transform; RL deconvolution; Richardson-Lucy deconvolution method; cone beam computed tomography system; directional modulation transfer function; directional plane spread function; estimated directional PlSF; full-width at half-maximum; full-width at tenth-maximum; ideal 3-D MTF; ideal directional MTF; ideal sphere phantom; local regions; nonnegativity constraint; plane integrals; quantitative evaluation; reconstructed sphere phantoms; spatially varying 3-D MTF; Computed tomography; Deconvolution; Detectors; Image reconstruction; Imaging phantoms; Phantoms; Three-dimensional displays; Cone beam computed tomography (CBCT); FDK; Richardson-Lucy (RL) deconvolution; directional modulation transfer function (MTF); sphere phantoms;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2014.2369524
Filename :
6953150
Link To Document :
بازگشت