DocumentCode
3662111
Title
Induction motor saliencies analysis using zero-sequence signal injection
Author
P. M. de la Barrera;G. R. Bossio;R. Leidhold
Author_Institution
Grupo de Electró
fYear
2015
fDate
6/1/2015 12:00:00 AM
Firstpage
518
Lastpage
523
Abstract
This paper presents an analysis of the magnetic saliencies in induction machines based on the injection of a zero sequence carrier. This way of injection allows evaluating those components of the admittance matrix which are not usually considered in the literature. The injection of the zero sequence carrier can easily be implemented, does not perturb the current control and the evaluation of its response is simple. It requires, however, access to the neutral point of the machine. The use of the zero sequence carrier for induction machines is a new approach that is evaluated in this paper. Experimental tests showed that two saliencies can be clearly identified in the carrier response: one due to the rotor bars and other due to the saturation in the main flux path. This would allow to estimate both, the rotor position and flux angle.
Keywords
"Rotors","Bars","Standards","Stators","Inverters","Pulse width modulation","Saturation magnetization"
Publisher
ieee
Conference_Titel
Industrial Electronics (ISIE), 2015 IEEE 24th International Symposium on
Electronic_ISBN
2163-5145
Type
conf
DOI
10.1109/ISIE.2015.7281521
Filename
7281521
Link To Document