Title :
Detecting positive-sequence component in active power filter under distorted grid voltage
Author :
Tuan Ngo; Quan Nguyen;Surya Santoso
Author_Institution :
Department of Electrical and Computer Engineering, The University of Texas at Austin, USA
fDate :
7/1/2015 12:00:00 AM
Abstract :
In distribution power system, an active power filter (APF) is installed at the point of common coupling (PCC) bus to eliminate harmonic currents injected by non-linear loads. The active power filter, therefore, needs to synchronize with the grid by employing a second-order-generalized-integrator frequency-locked loop (SOGI-FLL) to detect the positive-sequence voltage component. If the grid is highly distorted by harmonic currents, it degrades the accuracy of SOGI-FLL estimation and the APF cannot get correct grid voltage characteristics. This paper introduces a new grid synchronization structure based on the SOGI-FLL under distorted voltage condition. The proposed structure behaves as a high-order filter to completely remove harmonic components and inherits advantages from SOGI-FLL. The grid voltage magnitude and frequency, thus, are detected precisely under distorted grid. Simulation results are presented to verify the proposed system performances.
Keywords :
"Harmonic analysis","Decision support systems","Frequency control","Synchronization","Power harmonic filters","Voltage control"
Conference_Titel :
Power & Energy Society General Meeting, 2015 IEEE
DOI :
10.1109/PESGM.2015.7286530