DocumentCode
3666221
Title
Optical Flow as a Tool for Cardiac Motion Estimation
Author
Emiro Ibarra;Rubén ;Villie Morocho;Pablo Vanegas
Author_Institution
Dept. Electron. y Comun., Univ. de los Andes, Merida, Venezuela
fYear
2015
fDate
7/1/2015 12:00:00 AM
Firstpage
173
Lastpage
178
Abstract
A sparse based algorithm for optical flow estimation is presented and compared with several classical optical flow estimation algorithms. The comparison is performed using several video sequences available from the Middlebury benchmark where the ground truth optical flow is known. The sparse algorithm attains competitive results with average angular errors as low as 2.09° and average magnitude errors as low as 0.100. The algorithms are also tested using a 4-D cardiac Magnetic Resonance Image (MRI) sequence. The sparse algorithm estimates an optical flow field that represents the motion of contraction during the systole interval.
Keywords
"Optical imaging","Adaptive optics","Estimation","Optical sensors","Magnetic resonance imaging","Biomedical optical imaging","Optical resonators"
Publisher
ieee
Conference_Titel
Computer Aided System Engineering (APCASE), 2015 Asia-Pacific Conference on
Type
conf
DOI
10.1109/APCASE.2015.38
Filename
7287015
Link To Document