• DocumentCode
    3666447
  • Title

    Novel calorimetry technique for pulsed wires

  • Author

    J. Baker;J. Gahl;P. Norgard;O. Azizi;A. El-Boher;G. Hubler;J. He;D. Pease

  • Author_Institution
    Department of Electrical and Computer Engineering, University of Missouri
  • fYear
    2014
  • fDate
    6/1/2014 12:00:00 AM
  • Firstpage
    388
  • Lastpage
    390
  • Abstract
    A novel calorimetry technique was used to determine the energy delivered to a wire during a fast, low energy pulse. Following earlier work at dc by McKubre, et al., at SRI International, the diagnostic was applied to fast pulses for the first time. The experiment consisted of a low mass deuterium loaded wire placed in a vacuum flask filled with liquid nitrogen. A mass flow meter was used to detect the change in the production rate of nitrogen gas from the liquid bulk to determine energy released from the wire. This high sensitive technique permits precise energy balance measurements. Calorimetry techniques will be discussed and results presented.
  • Keywords
    "Wires","Palladium","Deuterium","Nitrogen","Liquids","Calorimetry","Physics"
  • Publisher
    ieee
  • Conference_Titel
    Power Modulator and High Voltage Conference (IPMHVC), 2014 IEEE International
  • Print_ISBN
    978-1-4673-7323-4
  • Type

    conf

  • DOI
    10.1109/IPMHVC.2014.7287291
  • Filename
    7287291