• DocumentCode
    3669380
  • Title

    Electrical capacitance tomography based imaging of high-contrast gas-liquid annular flow

  • Author

    Jin Zheng;Yi Li;Lihui Peng

  • Author_Institution
    Tsinghua National Laboratory for Information Science and Technology, Department of Automation, Tsinghua University, Beijing, China
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Gas-liquid annular flow with thin thickness often occurs in industry scenario and can be generated in laboratory for research. Imaging of gas-liquid annular flow can derive the thickness of the annular flow, further more calculate the gas liquid ratio, as well as help monitor the status of the gas-liquid annular flow in the process. In this paper, an electrical capacitance tomography (ECT) based method for imaging of gas-liquid annular flow is introduced, which focuses on image reconstruction and estimation of annulus thickness with high-contrast dielectric. The cross-section image is reconstructed from the compensated capacitances of an ECT sensor and is used to estimate the liquid film thickness.
  • Keywords
    "Capacitance","Image reconstruction","Permittivity","Electrodes","Liquids","Imaging","Films"
  • Publisher
    ieee
  • Conference_Titel
    Imaging Systems and Techniques (IST), 2015 IEEE International Conference on
  • Type

    conf

  • DOI
    10.1109/IST.2015.7294470
  • Filename
    7294470