• DocumentCode
    3670242
  • Title

    Real-time control for robotic hand application based on pressure sensor measurement

  • Author

    Ahmed M. ALmassri;Mostafa B. Abuitbel;W.Z. WanHasan;S A. Ahmad;Ahmad H. Sabry

  • Author_Institution
    Department of Electrical and Electronics Engineering, Universiti Putra Malaysia (UPM), 43400 Selangor, MALAYSIA
  • fYear
    2014
  • Firstpage
    80
  • Lastpage
    85
  • Abstract
    This paper presents the use of data acquisition (DAQ) device and LabVIEW program to evaluate and measure the pressure distribution for real-time robotic hand applications. An analog conditioning circuit has been implemented to calibrate and extract data from the utilized sensors to be processed by the DAQ and LabVIEW. Furthermore, an adequate signal processing analysis is performed on acquired data to investigate the desired measurements of pressure distribution for the robotic hand control purpose. This framework is considered as one of the techniques that can be used for robotic hand applications based on pressure sensor distribution and real-time monitored through the LabVIEW.
  • Keywords
    "Robot sensing systems","Service robots","Data acquisition","Monitoring","Biomedical monitoring","Reliability"
  • Publisher
    ieee
  • Conference_Titel
    Robotics and Manufacturing Automation (ROMA), 2014 IEEE International Symposium on
  • Type

    conf

  • DOI
    10.1109/ROMA.2014.7295866
  • Filename
    7295866