Title :
Fast charge oil switch jitter measurements
Author :
W. C. Nunnally;M. Lara
Author_Institution :
Applied Physical Electronics, LC, Austin, TX 78734
fDate :
5/1/2015 12:00:00 AM
Abstract :
The parameters for fast charged (tens of ns) Self Break Oil Switches (breakdown voltage, temporal variation (jitter) and effective dielectric strength) are not plentiful in the literature. This paper presents the breakdown and jitter parameters for standard transformer oil up to voltages of 700 kV. In addition, the design and operation of a simple experiment to measure the switching parameters as well as diagnostic design, calibration, and modeling of the experiment are discussed. Several electrode materials were investigated with both polarities for point plane geometries.
Keywords :
"Electric breakdown","Dielectric liquids","Dielectrics"
Conference_Titel :
Pulsed Power Conference (PPC), 2015 IEEE
Electronic_ISBN :
2158-4923
DOI :
10.1109/PPC.2015.7296984