• DocumentCode
    3671134
  • Title

    Thyratron replacement for the spallation neutron source linac extraction kicker PFN system

  • Author

    R. Saethre;B. Morris;H. Sanders

  • Author_Institution
    Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) 1 Bethel Valley Road, Oak Ridge, TN 37831 USA
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The Spallation Neutron Source (SNS) extraction kicker system is a high power 60 hertz pulsed power system. [1] The system consists of fourteen identical modulators, each driving a magnet to extract a proton beam from the accumulator ring through the beam transfer line to the target. Each modulator is a Blumlein Pulse Forming Network (PFN) with a fast high current switching thyratron and low inductance capacitor banks. The thyratron switches have relatively short life times, high replacement cost, long lead-time and require routine adjustments to maintain low timing jitter and drift. [2] A solid-state thyristor based high voltage switch has been developed as a direct replacement for the thyratron. [3] This paper describes the configuration, test stand and production kicker performance of the thyristor and PFN. In addition, the development of a magnetic switch to decrease magnet current rise time is discussed.
  • Keywords
    "Electron tubes","Rectifiers","Thyristors","Jitter","Switches","Delays","Saturation magnetization"
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference (PPC), 2015 IEEE
  • ISSN
    2158-4915
  • Electronic_ISBN
    2158-4923
  • Type

    conf

  • DOI
    10.1109/PPC.2015.7297034
  • Filename
    7297034