DocumentCode :
3675785
Title :
Determination of the inductances of a salient-pole synchronous machine without damper winding based on the voltage equation of a single coil in the stator winding
Author :
O. Misir;B. Ponick
Author_Institution :
Institute for Drive Systems and Power Electronics, Leibniz Universitä
fYear :
2015
Firstpage :
117
Lastpage :
123
Abstract :
An improved model for calculating the current distribution of salient-pole synchronous machines with internal faults in the stator winding is established using the multi-loop method. For this purpose, a good knowledge of the time-depending inductances is necessary. In this paper, a calculation method is presented to determine the mutual and self-inductances of the stator coils as well as the mutual inductances between the stator coils and the field winding of a salient-pole synchronous machine without damper winding. The method presented here considers the analytical calculation of the magnetic flux density based on the field excitation and the time-depending air-gap permeance function of the salient-pole synchronous machine.
Keywords :
Decision support systems
Publisher :
ieee
Conference_Titel :
Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED), 2015 IEEE 10th International Symposium on
Type :
conf
DOI :
10.1109/DEMPED.2015.7303678
Filename :
7303678
Link To Document :
بازگشت