DocumentCode :
3675863
Title :
On the human blood permittivity: Model parameters and substitution material for mmWave applications
Author :
Christoph Baer;Christian Schulz;Gordon Notzon;Ilona Rolfes;Thomas Musch
Author_Institution :
Institute of Electronic Circuits, Ruhr-University Bochum, Bochum, 44801, Germany
fYear :
2015
Firstpage :
30
Lastpage :
31
Abstract :
In this contribution, we present latest measurement results on human blood permittivity within the frequency range from 10GHz to 40GHz. Because bio sensor testing inside of real human blood is often critical, we propose a substitution material that is nonhazardous and unperishable. Furthermore, corresponding parameters for the advanced Cole-Cole model are presented for all investigated materials.
Keywords :
"Blood","Permittivity","Permittivity measurement","Sensors","Dielectrics","Sugar","Frequency measurement"
Publisher :
ieee
Conference_Titel :
RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO), 2015 IEEE MTT-S 2015 International Microwave Workshop Series on
Type :
conf
DOI :
10.1109/IMWS-BIO.2015.7303760
Filename :
7303760
Link To Document :
بازگشت