• DocumentCode
    3678268
  • Title

    Automatic Diabetic Retinopathy detection using OMFR with minimum cross entropy threshold

  • Author

    Saumitra Kumar Kuri

  • Author_Institution
    Department of Applied Physics, Electronics &
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Retinal blood vessels damaged from diabetic retinopathy can cause vision loss. Diabetic Retinopathy (DR) detection, poor quality retinal image makes more difficult the analysis for ophthalmologist. In this paper presents a new automatic method of blood vessels extraction with a real time process using optimized matched filter with minimum cross entropy threshold. Minimum cross entropy threshold is effective in the threshold technique; it could be very time-consuming in normal or abnormal retinal image for vessels segmentation. The performance of this proposed method was calculated on DRIVE database. This method computational time of whole MATLAB process was taken in a real time for each retinal image.
  • Keywords
    "Kernel","Matched filters","Gray-scale","Gold","Standards","Real-time systems","Indexes"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Engineering and Information Communication Technology (ICEEICT), 2015 International Conference on
  • Type

    conf

  • DOI
    10.1109/ICEEICT.2015.7307495
  • Filename
    7307495