• DocumentCode
    3678724
  • Title

    The load current sensing method in the multiple output high insulation voltage transformer

  • Author

    Andrzej Wyżga;Jacek Gruca;Aleksander Polit;Georgios Papafotiou

  • Author_Institution
    ABB Sp. z o.o., Starowiś
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    Some power supplies do not require accurate current feedback to function properly. In many cases the information about the output current is only needed to make sure that the power supply is not overloaded. This paper describes a sensing method of individual secondary currents of a four channel power supply built using a single core transformer, by sensing the currents flowing in separate primary windings. Each secondary current could be sensed on the primary side of the high insulation voltage transformer with sufficient accuracy to assure proper fault handling strategy for the power supply.
  • Keywords
    "Windings","Insulation","Power supplies","Power transformer insulation","Couplings","Sensors","Magnetic resonance"
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE´15 ECCE-Europe), 2015 17th European Conference on
  • Type

    conf

  • DOI
    10.1109/EPE.2015.7309100
  • Filename
    7309100