DocumentCode :
3678724
Title :
The load current sensing method in the multiple output high insulation voltage transformer
Author :
Andrzej Wyżga;Jacek Gruca;Aleksander Polit;Georgios Papafotiou
Author_Institution :
ABB Sp. z o.o., Starowiś
fYear :
2015
Firstpage :
1
Lastpage :
8
Abstract :
Some power supplies do not require accurate current feedback to function properly. In many cases the information about the output current is only needed to make sure that the power supply is not overloaded. This paper describes a sensing method of individual secondary currents of a four channel power supply built using a single core transformer, by sensing the currents flowing in separate primary windings. Each secondary current could be sensed on the primary side of the high insulation voltage transformer with sufficient accuracy to assure proper fault handling strategy for the power supply.
Keywords :
"Windings","Insulation","Power supplies","Power transformer insulation","Couplings","Sensors","Magnetic resonance"
Publisher :
ieee
Conference_Titel :
Power Electronics and Applications (EPE´15 ECCE-Europe), 2015 17th European Conference on
Type :
conf
DOI :
10.1109/EPE.2015.7309100
Filename :
7309100
Link To Document :