Title :
Failure to short-circuit capability of emerging direct-lead-bonding power module. Comparison with standard interconnection. Application for dedicated fail-safe and fault-tolerant converters embedded in critical applications
Author :
William Sanfins;Frédéric Richardeau;Damien Risaletto;Gaël Blondel;Michael Chemin;Philippe Baudesson
Author_Institution :
Université
Abstract :
The Direct-Lead-Bonding (DLB) interconnection appears to be a promising technology for power-module (PM). Nevertheless, the absence of wire-fuse-effect in case of extreme failure, compared to classical wire-bonding, leads authors to rethink fail-safe and fault-tolerant strategies for critical converter. Therefore, this paper will provide a comparative study between these two designs in terms of failure-mode and post-fault high-current capability.
Keywords :
"Resistance","Circuit faults","Inverters","Resins","Bonding","Fault tolerance","Fault tolerant systems"
Conference_Titel :
Power Electronics and Applications (EPE´15 ECCE-Europe), 2015 17th European Conference on
DOI :
10.1109/EPE.2015.7309355