    Multi-step Simplified Optimal Trajectory Control (SOTC) for fast transient response of high frequency LLC converters

  • Author

    Chao Fei;Fred C. Lee;Qiang Li

  • Author_Institution
    Center for Power Electronics Systems Virginia Tech, Blacksburg, VA 24061 USA
  • fYear
    2015
  • Firstpage
    2064
  • Lastpage
    2071
  • Abstract
    This paper proposes Multi-step Simplified Optimal Trajectory Control (SOTC) for the high frequency LLC converters. SOTC can improve the transient performance of the LLC converters by immediately changing the pulse width of the primary driving signal during the load transient. However, the implementation of SOTC requires high-performance digital controllers. The proposed Multi-step SOTC calculates the trajectory based on only the output voltage and the load current, and settles the resonant tank within multi steps. With the proposed Multi-step SOTC, low-cost controllers can be used to control the high frequency LLC converters with the state-trajectory control concept. The number of steps in multi-step SOTC is selected based on the speed of the controller and the switching frequency of the LLC converters. Experimental results are demonstrated on a 500kHz 1kW 400V/12V LLC converter.
  • Keywords
    "Trajectory","Switching frequency","Transient analysis","Delays","Transient response","Resonant frequency"
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2015 IEEE
  • ISSN
    2329-3721
  • Electronic_ISBN
    2329-3748
  • Type

    conf