DocumentCode :
3679512
Title :
On-Line Turn Fault Detection of Interior Permanent Magnet Machines Using the Pulsating-Type Voltage Injection
Author :
Shih-Chin Yang
Author_Institution :
National Taiwan University, Taipei, Taiwan, R.O.C.
fYear :
2015
Firstpage :
2200
Lastpage :
2207
Abstract :
This paper proposes a stator winding fault diagnosis for interior permanent magnet (PM) machines based on the pulsating-type voltage injection. By superimposing a pulsating voltage on d-axis with respect to the rotor-referred synchronous frame, measurable winding fault reflected signals occur in the injection induced current ripples. Comparing to prior diagnostic techniques, the proposed injection method is immune to the rotor saliency because saliency reflected current harmonic is decoupled once the pulsating voltage is exactly injected on rotor d-axis. It results in the improved fault diagnostic performance on interior PM (IPM) machines as well as other salient machines. An IPM machine with three sets of turn-to-turn short is built to verify the proposed fault diagnostic method.
Keywords :
"Harmonic analysis","Rotors","Power harmonic filters","Circuit faults","Inductance","Fault detection","Fault diagnosis"
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2015 IEEE
ISSN :
2329-3721
Electronic_ISBN :
2329-3748
Type :
conf
DOI :
10.1109/ECCE.2015.7309970
Filename :
7309970
Link To Document :
بازگشت