DocumentCode
3679550
Title
Closed-Loop Pulse Energy Modulation of a Three-Switch Buck-Boost Inverter
Author
Shuang Xu;Shuying Yang;Riming Shao;Liuchen Chang
Author_Institution
Department of Electrical and Computer Engineering, University of New Brunswick Fredericton, Canada
fYear
2015
Firstpage
2485
Lastpage
2489
Abstract
This paper proposed a closed-loop pulse energy modulation (PEM) control method for a grid-connected three-switch buck-boost inverter. The three-switch buck-boost inverter was studied for both discontinuous conduction mode (DCM) and continuous conduction mode (CCM). Simulations verified the closed-loop PEM control method provided high-quality current injected to the grid and insensitivity to component parametric deviations and voltage variations. The controlled inverter transferred energy from dc source to ac grid efficiently and achieved a low-THD sinusoidal output current. Therefore, it can be concluded that the proposed control method is suited for buck-boost inverters in distributed generation systems.
Keywords
"Inverters","Switches","Inductors","Modulation","Inductance","Mathematical model","Power harmonic filters"
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2015 IEEE
ISSN
2329-3721
Electronic_ISBN
2329-3748
Type
conf
DOI
10.1109/ECCE.2015.7310009
Filename
7310009