DocumentCode :
3679624
Title :
Study on an accurate iron loss calculation method considering the non-uniformity of the magnetic flux density
Author :
Hiroaki Sato;Toshihisa Shimizu
Author_Institution :
Tokyo Metropolitan University, Japan
fYear :
2015
Firstpage :
3032
Lastpage :
3039
Abstract :
While high frequency switching of power converters can enable inductor volume reductions, large temperature increases occur in such inductors as their thermal resistance increases. Therefore, the ability to accurately calculate inductor iron losses is necessary when designing high-power-density converters. In the present paper, the authors propose an accurate iron loss calculation method for inductors that works by taking into consideration the non-uniformity of the magnetic flux density in their cores.
Keywords :
"Magnetic cores","Iron","Loss measurement","Magnetic flux density","Inductors","Windings"