DocumentCode
3679774
Title
On line detection of inverter fed AC machine insulation health state using high frequency voltage excitation
Author
T. M. Wolbank
Author_Institution
Inst. of Energy Syst. &
fYear
2015
Firstpage
4084
Lastpage
4090
Abstract
Condition monitoring is gaining more and more importance in the past few years. As inverter fed operation puts additional stress on the machine´s insulation system a breakdown of a drive system associated with costly outage of industrial processes or production plants is getting more likely. To enable a monitoring of the insulation system health state before an actual short circuit and breakdown occurs extensive test procedures are usually necessary that need both, additional equipment as well as disconnected drive. In order to enable a continuous monitoring a method is presented that enables the detection of changes in the machines insulation system during operation of the inverter. The method is based on a voltage excitation of the machine with a specific frequency range and measuring the corresponding current reaction. By observing changes at a specific frequency range, an insulation health indicator can be calculated that is able to detect deteriorations before an actual short circuit establishes. No additional sensors or measurement equipment is needed and the method can be implemented in modern inverter fed drives with minimum changes of configuration.
Keywords
"Insulation","Frequency measurement","Inverters","Current measurement","Capacitance","Voltage measurement","Sensors"
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2015 IEEE
ISSN
2329-3721
Electronic_ISBN
2329-3748
Type
conf
DOI
10.1109/ECCE.2015.7310236
Filename
7310236