Title :
Detecting the optimal active contour in the computed tomography image by using entropy to choose coefficients in energy equation
Author_Institution :
Laboratory for Analysis and Architecture of System, CNRS, University of Toulouse 7 Avenue du Colonel Roche - 31077 Toulouse Cedex 4, France
Abstract :
In this paper, we present the method that it uses image entropy to choose coefficients in energy equation of active contour. We calculate the entropy of the computed tomography image with each pair of tension and elastic coefficient. When the active contour is optimal, the image has minimum entropy (i.e. the image is less change). In addition to solve energy equation (the optimal problem), we use dynamic programming with constraints, these increase computed efficiency of method. They are compound conditions to detect the optimal active contour in computed tomography image.
Keywords :
"Active contours","Entropy","Dynamic programming","Computed tomography","Mathematical model","Uncertainty","Image quality"
Conference_Titel :
Systems, Signals and Image Processing (IWSSIP), 2015 International Conference on
Electronic_ISBN :
2157-8702
DOI :
10.1109/IWSSIP.2015.7313932