• DocumentCode
    3684141
  • Title

    A comparison of open-loop and closed-loop adaptive calibration for pattern recognition based myoelectric control

  • Author

    Jiayuan He;Dingguo Zhang;Xinjun Sheng;Xiangyang Zhu

  • Author_Institution
    State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, 200240, China
  • fYear
    2015
  • Firstpage
    1144
  • Lastpage
    1147
  • Abstract
    This study presented a closed-loop adaptive calibration (CLAC) scheme where subjects could get instantaneous feedback of their movements and alter their motions immediately to update the model parameters to enhance its ability. The real-time performance was compared between the conventional open-loop calibration (OLC) and the presented CLAC based on three metrics (motion-selection time, motion-completion time and motion-completion rate). The CLAC performed slightly better than the OLC, but the difference was not significant. This was the first study designed to investigate the effects of CLAC for pattern recognition-based myoelectric control (discrete movement). The CLAC could be potentially applied in the multiuser interface to make the adaptation of the common model to a novel user efficiently and flexibly.
  • Keywords
    "Calibration","Electromyography","Pattern recognition","Training","Adaptation models","Wrist","Real-time systems"
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE
  • ISSN
    1094-687X
  • Electronic_ISBN
    1558-4615
  • Type

    conf

  • DOI
    10.1109/EMBC.2015.7318568
  • Filename
    7318568