DocumentCode :
3685350
Title :
Heart Rate monitoring during physical exercise using wrist-type photoplethysmographic (PPG) signals
Author :
Amirhosein Khas Ahmadi;Parsa Moradi;Mahan Malihi;Sajjad Karimi;Mohammad B. Shamsollahi
Author_Institution :
Biomedical Signal and Image Processing Lab. (BiSIPL), Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
fYear :
2015
Firstpage :
6166
Lastpage :
6169
Abstract :
Heart rate monitoring using wrist-type using photoplethysmographic (PPG) signals during subjects´ intensive exercises is a challenging problem, since signals are strongly affected by motion artifacts caused by unexpected movements. This paper presents a method that uses both time and frequency characteristics of signals; using sparse signal reconstruction for high-resolution spectrum estimation. Experimental results on type data sets recorded from 12 subjects during fast running at peak speed of 15 km/hour. The results have a performance with the average absolute error being 1.80 beat per minute.
Keywords :
"Heart rate","Estimation","Acceleration","Harmonic analysis","Power harmonic filters","Monitoring"
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE
ISSN :
1094-687X
Electronic_ISBN :
1558-4615
Type :
conf
DOI :
10.1109/EMBC.2015.7319800
Filename :
7319800