DocumentCode
3685389
Title
HoG feature based detection of tissue deformations in ultrasound data
Author
J. Czajkowska;B. Pycínski;E. Pietka
Author_Institution
Faculty of Biomedical Engineering, Silesian University of Technology, ul. Roosevelta 40, 41-800 Zabrze, Poland
fYear
2015
Firstpage
6326
Lastpage
6329
Abstract
The fast development of imaging techniques during last decades makes it possible to introduce intra-operative visualization as the integral part of surgical procedures. Therefore, the automated analysis of intra-operative ultrasound images is appreciated. The image processing, registration and visualization techniques help in better understanding and locate the operated region. To meet these needs, the paper presents an advanced algorithm for automated detection of tissue deformations caused by a biopsy needle. For this, feature set of Histogram of Gradients (HoG) is introduced. The extracted feature vectors are then used in image cell clustering step resulting in tissue deformation as well as biopsy needle detection. The applied there Kernelized Weighted C-Means clustering technique enables robust and accurate needle detection proven by sensitivity and specificity values at levels of 0.846 and 0.99, respectively.
Keywords
"Needles","Biopsy","Phantoms","Feature extraction","Clustering algorithms","Histograms","Breast"
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE
ISSN
1094-687X
Electronic_ISBN
1558-4615
Type
conf
DOI
10.1109/EMBC.2015.7319839
Filename
7319839
Link To Document