Title :
Evaluation of experimentally measured non-stationary oscillations in gyrotrons using adequate simulation methods
Author :
F. Braunmueller;S. Alberti;T.-M. Tran;J. Genoud;Q. Vuillemin;J.-P. Hogge;M.Q. Tran
Abstract :
In order to properly simulate cases in which gyrotrons exhibit fast temporally varying oscillations, such as non-stationary oscillations or possible dynamic After-Cavity Interaction (ACI), an adequate model for the beam-wave interaction has to be used. We will show that the commonly used assumption of considering a constant wave-field envelope during the electron transit time has to be abandoned. The appropriate model (reduced 1D Particle-In-Cell (PIC) model) is briefly presented and the implications of using an inadequate model are illustrated. For the case of a 150W/260GHz gyrotron, non-stationary simulations with the new model will be compared to experiment and used in order to investigate the underlying mechanism of these oscillations.
Keywords :
"Oscillators","Gyrotrons","Plasmas","Adaptation models","Time-frequency analysis","Mathematical model","Physics"
Conference_Titel :
Infrared, Millimeter, and Terahertz waves (IRMMW-THz), 2015 40th International Conference on
Electronic_ISBN :
2162-2035
DOI :