DocumentCode
3692236
Title
Performance improvement of GC/SAW gas sensor system
Author
Jiuling Liu;Minghua Liu;Shitang He
Author_Institution
Institute of Acoustics, Chinese Academy of Sciences, Beijing, China
fYear
2015
Firstpage
1
Lastpage
3
Abstract
This paper presented an optimal design on GC/SAW gas sensors by adjusting the resonant cavity of the SAW device used in the sensor system. Experimental results from the developed sensor system towards dimethyl methylphosphonate (DMMP) detection indicated that short the resonant cavity of the SAW resonator will concentrate the acoustic energy to the central area, hence, higher sensitivity was achieved.
Keywords
"Surface acoustic waves","Surface acoustic wave devices","Gas detectors","Cavity resonators","Performance evaluation","Oscillators"