• DocumentCode
    3692535
  • Title

    A PMN-PT micromachined 1–3 composite circular array for IVUS

  • Author

    Sibo Li;Xiaoning Jiang;Jian Tian;Pengdi Han;Chao Zhang

  • Author_Institution
    Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, 27606, USA
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In this paper, a single crystal PMN-PT micromachined 1-3 composite circular array (50 element, ~2.2 mm in diameter) was developed for intravascular ultrasound (IVUS) imaging. Micromachined 1-3 composites with frequency of XX MHz were first fabricated and tested. Array elements with a pitch of 140-micron were interconnected via a customized flexible circuit. Pulse-echo tests showed the average center frequency of 40 MHz and the -6 dB fractional bandwidth of 62% for array elements. The -20 dB pulse length was evaluated as 118 ns. The measured crosstalk is less than - 24 dB between adjacent elements. An image of 50 μm steel wire targets was acquired by stacking multiple A-lines. The results demonstrated beam widths exceeding 70 μm axially. Those results imply the great potential of the developed array transducer for the high frequency medical imaging.
  • Keywords
    "Arrays","Imaging","Impedance","Ultrasonic imaging","Transducers","Loss measurement","Steel"
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2015 IEEE International
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2015.0117
  • Filename
    7329529