Title :
Spectroscopy in a micro-fabricated Rb cell with anti-relaxation wall-coating
Author :
Matthieu Pellaton;Christoph Affolderbach;Gaetano Mileti;Rahel Straessle;Yves P?tremand;Danick Briand;Nico F. de Rooij
Author_Institution :
Laboratoire Temps-Fr?quence (LTF), Institut de Physique, University of Neuch?tel, Neuch?tel, Switzerland
fDate :
6/1/2014 12:00:00 AM
Abstract :
We report on the realization and spectroscopic evaluation of a micro-fabricated Rb vapor cell equipped with an anti-relaxation OTS wall coating. By combining different spectroscopic results, we can exclude a hypothetical buffer-gas contamination of the cell as cause of the narrow double-resonance (DR) signals observed. We thus conclude that the narrow DR signal linewidth is due to the anti-relaxation wall-coating present in the cell. This realization presents interests in view of applications in miniaturized atomic devices such as atomic clocks, magnetometers, and others.
Keywords :
"Coatings","Absorption","Contamination","Pollution measurement","Reservoirs","Atomic clocks"
Conference_Titel :
European Frequency and Time Forum (EFTF), 2014
DOI :
10.1109/EFTF.2014.7331561