• DocumentCode
    3701613
  • Title

    Contribution to charging of battery with pulses

  • Author

    Szab? Levente

  • Author_Institution
    Faculty of Electronics, Telecommunications and Information Technology, Technical University of Cluj-Napoca, Romania
  • fYear
    2015
  • Firstpage
    165
  • Lastpage
    168
  • Abstract
    The charging of Lead-acid battery with pulses has other advantages besides the desulfation phenomenon on electrodes. The quantity of energy that is invested into charging the battery with pulses doesn´t have an homogenous graph with regards to the variation of duty cycle. The experimental measurements of quantities of energy for charging of battery show the existence of maxims and minims on the frequency domain between 33 Hz - 100 kHz with various duty cycle. This fact is caused by the physical and electrochemical properties of particles, which determine the speed of motion and reaction under electrical field.
  • Keywords
    "Batteries","Voltage measurement","Battery charge measurement","Current measurement","Electronics packaging","Lead","Energy measurement"
  • Publisher
    ieee
  • Conference_Titel
    Design and Technology in Electronic Packaging (SIITME), 2015 IEEE 21st International Symposium for
  • Type

    conf

  • DOI
    10.1109/SIITME.2015.7342318
  • Filename
    7342318