DocumentCode
3708419
Title
Aging effect on oil cooling capacity of a non-guided disc windings power transformer
Author
K. S. Kassi;I. Fofana;M. I. Farinas;C. Volat
Author_Institution
Insulating Liquids and Mixed Dielectrics for Electrotechnology (ISOLIME), Universit? du Qu?bec ? Chicoutimi, Canada
fYear
2015
Firstpage
804
Lastpage
807
Abstract
Many transformers around the world are serving close to or beyond their design life. In these important asset, cores and coils losses cause heating and energy losses within the core decreasing their efficiency and shortening their life expectancy. The aim of this contribution was to study the aging effect on mineral oil cooling capacity of power transformers. The oil aging effect on its viscosity and its physicochemical properties is also reported. A 2D axisymmetric thermo-fluid numerical model was developed with COMSOL Multiphysics to study the cooling capability of oil aged at different levels. The results show that the oil viscosity increase considerably with aging and its physicochemical properties are also affected. It was found that sludge as oil oxidation byproduct contributes to the widening of hot spots in the transformers with non-guided disc windings.
Keywords
"Aging","Viscosity","Power transformer insulation","Oil insulation","Mathematical model"
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena (CEIDP), 2015 IEEE Conference on
Print_ISBN
978-1-4673-7496-5
Type
conf
DOI
10.1109/CEIDP.2015.7352049
Filename
7352049
Link To Document