• DocumentCode
    3708478
  • Title

    Investigating flashover behaviour of silicone rubber insulators under contaminated conditions

  • Author

    Arshad;A. Nekahi;S.G. McMeekin;M. Farzaneh

  • Author_Institution
    School of Engineering and Built Environment, Glasgow Caledonian University, Cowcaddens Road, United Kingdom
  • fYear
    2015
  • Firstpage
    856
  • Lastpage
    859
  • Abstract
    Flashover behaviour of silicone rubber insulators were analysed under contaminated conditions in this paper. The modified IEC 60507 Standard was used to simulate pollution deposition on the insulator surface. Experiments were carried out at different pollution level and changing leakage distances to investigate the behaviour of silicone rubber insulators. It was shown experimentally that flashover voltage is highly dependent on pollution level and leakage distance. The result of this study can be used to investigate the ageing of silicone rubber insulators and their selection for contaminated and wet environments.
  • Keywords
    "Flashover","Pollution","Leakage currents","Surface contamination","Rubber","Voltage measurement"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena (CEIDP), 2015 IEEE Conference on
  • Print_ISBN
    978-1-4673-7496-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.2015.7352108
  • Filename
    7352108