DocumentCode :
3711138
Title :
Spectral responsivity of WPVS reference cells under varied temperatures and its influence on performance measurements beyond STC
Author :
Sebastian Dittmann;Mauro Pravettoni;Loris Manni;Gabi Friesen
Author_Institution :
University of Applied Sciences and Art of Southern Switzerland, Institute of Applied Sustainability to the Built Environment, Canobbio, CH-6952, Switzerland
fYear :
2015
fDate :
6/1/2015 12:00:00 AM
Firstpage :
1
Lastpage :
4
Abstract :
The authors present the results of a study which investigates the temperature dependence of the spectral responsivity of WPVS reference cells and its influence on measurement uncertainties for performance measurements beyond standard test conditions (STC). Five crystalline unfiltered reference cells from three different manufacturers were spectrally characterized at different temperatures. The authors calculated the temperature coefficient of the reference cells at different wavelengths and temperature ranges and showed significant deviations from the temperature coefficient of the calibration certificate. However, it is shown that the tested commercial reference cells have a non-linear behavior for a temperature range of 25 to 60°C and therefore they cannot be used for measurements at high temperatures e.g. outdoor applications or temperature coefficient measurements. The report demonstrates how this affects performance measurements above 25°C.
Keywords :
"Temperature measurement","Calibration","Temperature distribution","Standards","Current measurement","Xenon"
Publisher :
ieee
Conference_Titel :
Photovoltaic Specialist Conference (PVSC), 2015 IEEE 42nd
Type :
conf
DOI :
10.1109/PVSC.2015.7355855
Filename :
7355855
Link To Document :
بازگشت