DocumentCode
3711781
Title
An efficient technique based on DORT method to locate multiple soft faults in wiring networks
Author
Moussa Kafal;Andrea Cozza;Lionel Pichon
Author_Institution
CentraleSup?lec, UMR 8507 CNRS, Universit? Paris-Sud, Universit? Pierre et Marie Curie, 11 rue Joliot-Curie, 91192 Gif-sur-Yvette, France
fYear
2015
Firstpage
339
Lastpage
344
Abstract
Decomposition of the time reversal operator (DORT) recently adopted to wiring fault detection and localization presented effectual results when dealing with a single soft fault along with complex network configurations. On the other hand, it failed in handling the task of locating multiple faults within even simple ones. In this paper, we propose an enhanced version of the standard DORT technique (EDORT) which is based on a complementary procedure enabling the accurate and selective localization of multiple soft faults in various wiring systems.
Keywords
"Scattering","Standards","Testing","Wiring","Circuit faults","Silicon","Wires"
Publisher
ieee
Conference_Titel
IEEE AUTOTESTCON, 2015
Type
conf
DOI
10.1109/AUTEST.2015.7356513
Filename
7356513
Link To Document