• DocumentCode
    3711794
  • Title

    ITA or ITEA a comprehensive dissimilarity

  • Author

    Larry V. Kirkland;Wayne Tjoland

  • Author_Institution
    WesTest Engineering Corp., 810 Shepard Lane, Farmington, Utah 84025, United States of America
  • fYear
    2015
  • Firstpage
    415
  • Lastpage
    421
  • Abstract
    Although it is assumed an Interface Test Adapter (ITA) is an Interface Test Adapter; this is not necessarily true. The whole concept of an Interface Test Adapter is to route Automatic Test Equipment (ATE) signals from the ATE to the Unit Under Test (UUT) and signals from the UUT to the ATE. Also, the ITA has the UUT connector and card guides (when testing circuit cards) so the UUT can be connected to the test equipment. However, there can profound differences between ITAs and ITA concepts. The profound difference between ITAs is the use of active components. Adding active components, over and above the standard noise reducing capacitors or load resistors (passive components), essentially makes the ITA part of the test equipment itself.
  • Keywords
    "Wires","Test equipment","Connectors","Grounding","Reliability","Instruments"
  • Publisher
    ieee
  • Conference_Titel
    IEEE AUTOTESTCON, 2015
  • Type

    conf

  • DOI
    10.1109/AUTEST.2015.7356526
  • Filename
    7356526