Title :
New shunt calorimeter for testing electric motors
Author :
L. Aarniovuori;W. Cao;H. Chen;N. Yang
Author_Institution :
Electrical Engineering, LUT School of Energy Systems, Lappeenranta, Finland
Abstract :
The determination of the power losses in the high-efficiency electric motors with distorted voltage and current waveforms is technically challenging and thus an alternative using the calorimetric measurement systems is gaining in popularity. Different types of calorimetric systems with their pros and cons have been proposed in the literature but they are generally limited in measurement accuracy and control complexity. This paper proposes a new shunt calorimeter used for measuring power losses in electrical motors to a high accuracy of 0.2%.
Keywords :
"Loss management","Voltage measurement","Energy efficiency","Electrical equipment","Thermal analysis"
Conference_Titel :
Industry Applications Society Annual Meeting, 2015 IEEE
DOI :
10.1109/IAS.2015.7356742