DocumentCode :
3712109
Title :
Performance of energy saving lamps on power quality and luminous properties under voltage decreasing 240V?100V
Author :
M. Yusrizal;P. Dupuis;N. I. Sinisuka;G. Zissis
Author_Institution :
Universite de Toulouse, LAPLACE, UMR 5213(CNRS, INPT, UPS), 118 route de Narbonne, 31062 Toulouse, France
fYear :
2015
Firstpage :
1
Lastpage :
8
Abstract :
As state-owned electricity company in Indonesia, PLN still has lack of capacity and long distribution network in several regions so that under nominal voltage still happens in those regions. Sometimes, a brownout strategy is still done to avoid outage, unfortunately it makes the voltage in area supplied by long network become worse in peak load. Lamps will operate at a lower voltage than their rating. Nowadays, energy saving lamps (ESLs) are widely used by customers in Indonesia. To investigate the effect of voltage decreasing on power quality and luminous properties, laboratory observations will be performed. Sixteen sample lamps consist of 5 CFLs lamps and 11 LEDs with different manufacturers and power ratings will be tested. The results of tests indicate that only a few of ESLs meet IEC 61000-3-2 requirements.
Keywords :
"Lighting","Light emitting diodes","Voltage control","Lamps","Fluorescent lamps"
Publisher :
ieee
Conference_Titel :
Industry Applications Society Annual Meeting, 2015 IEEE
Type :
conf
DOI :
10.1109/IAS.2015.7356864
Filename :
7356864
Link To Document :
بازگشت