DocumentCode :
3715361
Title :
Remedy for open-circuit fault of 4-phase permanent magnet fault tolerant motor
Author :
Si Binqiang;Zhu Jihong
Author_Institution :
Beihang University, Beijing Research Institute of Precise Mechatronics and Controls, Beijing, China
fYear :
2015
Firstpage :
49
Lastpage :
53
Abstract :
With multiple single-phase lanes, and each driven by independent H-bridge power converters, permanent-magnet fault-tolerant motors inherently offer isolated phases and fault-tolerant capability. It is assumed that there is an open-circuit fault detected in the Phase A. In order to keep torque performance invariant during the faulty operation, a pertinent fault tolerant strategy is separately presented, derived and tested. Based on a series of experiments on a test bench, the effectiveness and validity of fault-tolerant capability and the strategy of the motor are verified.
Keywords :
"Torque","Fault tolerance","Fault tolerant systems","Circuit faults","Windings","Permanent magnet motors","Rotors"
Publisher :
ieee
Conference_Titel :
Computer and Computational Sciences (ICCCS), 2015 International Conference on
Print_ISBN :
978-1-4799-1818-8
Type :
conf
DOI :
10.1109/ICCACS.2015.7361321
Filename :
7361321
Link To Document :