DocumentCode :
3715621
Title :
Research on Parallel Shunt Hybrid Active Power Filter with repetitive LADRC algorithm
Author :
Dan Qin; Guang Zeng
Author_Institution :
Department of Electric Engineering Xi´an University of Technology, China
fYear :
2015
Firstpage :
1
Lastpage :
6
Abstract :
Parallel Shunt Hybrid Active Power Filter(SHAPF) has the advantage of high pressure and can dynamically compensate each harmonic, which is becoming popular harmonic control[3] devices. Liner auto disturbance rejection controller (LADRC) does not rely on the controlled object model, which solves the problem of uncertainty model about SHAPF. But it can only offset a part nonlinear of the system, there is still uncertainty. In this paper, repetitive control algorithm is added and Repetitive Linear Auto Disturbance Rejection Control (RLADRC) is proposed to improve compensation accuracy. Matlab/Simulink is applicated to simulate them, and the experiment platform of SHAPF is built, the simulink and experiment results show that the proposed method can effectively eliminate the tracking error, so as to improve the robustness of the system.
Keywords :
"Harmonic analysis","Power harmonic filters","Active filters","Heuristic algorithms","Mathematical model","Control systems"
Publisher :
ieee
Conference_Titel :
Future Energy Electronics Conference (IFEEC), 2015 IEEE 2nd International
Print_ISBN :
978-1-4799-7655-3
Type :
conf
DOI :
10.1109/IFEEC.2015.7361594
Filename :
7361594
Link To Document :
بازگشت