DocumentCode :
37178
Title :
Alternating Direction Method of Multiplier for Tomography With Nonlocal Regularizers
Author :
Se Young Chun ; Dewaraja, Yuni K. ; Fessler, Jeffrey A.
Author_Institution :
Dept. of Electr. Eng. & Comput. Sci., Univ. of Michigan, Ann Arbor, MI, USA
Volume :
33
Issue :
10
fYear :
2014
fDate :
Oct. 2014
Firstpage :
1960
Lastpage :
1968
Abstract :
The ordered subset expectation maximization (OSEM) algorithm approximates the gradient of a likelihood function using a subset of projections instead of using all projections so that fast image reconstruction is possible for emission and transmission tomography such as SPECT, PET, and CT. However, OSEM does not significantly accelerate reconstruction with computationally expensive regularizers such as patch-based nonlocal (NL) regularizers, because the regularizer gradient is evaluated for every subset. We propose to use variable splitting to separate the likelihood term and the regularizer term for penalized emission tomographic image reconstruction problem and to optimize it using the alternating direction method of multiplier (ADMM). We also propose a fast algorithm to optimize the ADMM parameter based on convergence rate analysis. This new scheme enables more sub-iterations related to the likelihood term. We evaluated our ADMM for 3-D SPECT image reconstruction with a patch-based NL regularizer that uses the Fair potential function. Our proposed ADMM improved the speed of convergence substantially compared to other existing methods such as gradient descent, EM, and OSEM using De Pierro´s approach, and the limited-memory Broyden-Fletcher-Goldfarb-Shanno algorithm.
Keywords :
image reconstruction; iterative methods; medical image processing; positron emission tomography; single photon emission computed tomography; 3D SPECT image reconstruction; ADMM parameter; De Pierro´s approach; OSEM algorithm; PET; alternating direction method of multiplier; convergence rate analysis; emission tomographic image reconstruction problem; fast image reconstruction; likelihood function; limited-memory Broyden-Fletcher-Goldfarb-Shanno algorithm; ordered subset expectation maximization algorithm; patch-based NL regularizer; patch-based nonlocal regularizers; transmission tomography; Approximation algorithms; Approximation methods; Convergence; Image reconstruction; Single photon emission computed tomography; Vectors; Alternating direction method of multiplier; emission tomography; nonlocal (NL) regularizer; ordered-subset expectation maximization (OSEM);
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2014.2328660
Filename :
6825888
Link To Document :
بازگشت